BugZero found this defect 118 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/17/2024
BIG-IP
BIG-IP F5OS-A
BIG-IP LTM
BIG-IP Velos
17.1.0
17.1.0.1
17.1.0.2
17.1.0.3
17.1.1
17.1.1.1
17.1.1.2
17.1.1.3
No fixed releases provided.
Severity: 3-Major ... Symptoms ... PVA dedicated mode will not work in F5OS tenants until pva flow eviction is disdabled. ... Impact ... PVA connections may not all be accelerated. ... They will not be using the neuron engine. ... Conditions ... Low latency license, dedicated mode enabled in the fastl4 profile. ... Workaround ... tmsh modify ltm profile fastl4 myfastl4 pva-flow-evict disabled