Operational Defect Database

BugZero found this defect 104 days ago.

F5 | 1462421

PVA connections are not re-accelerated after a failover.

Last update date:

5/16/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

15.1.0

15.1.0.1

15.1.0.2

15.1.0.3

15.1.0.4

15.1.0.5

15.1.1

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1462421: PVA connections are not re-accelerated after a failover. ... Last Modified: May 16, 2024 ... Symptoms ... After a failover, not all PVA-accelerated flows are accelerated on the new peer. ... Impact ... No PVA acceleration for mirrored flows on the newly active unit. ... Conditions ... -- PVA acceleration enabled -- Connection mirroring ... Workaround ... Delete the affected flows and then cause them to be re-created. ... Disable HA mirroring.