BugZero found this defect 104 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/16/2024
BIG-IP
BIG-IP LTM
15.1.0
15.1.0.1
15.1.0.2
15.1.0.3
15.1.0.4
15.1.0.5
15.1.1
15.1.2
15.1.2.1
15.1.3
15.1.3.1
15.1.4
No fixed releases provided.
Bug ID 1462421: PVA connections are not re-accelerated after a failover. ... Last Modified: May 16, 2024 ... Symptoms ... After a failover, not all PVA-accelerated flows are accelerated on the new peer. ... Impact ... No PVA acceleration for mirrored flows on the newly active unit. ... Conditions ... -- PVA acceleration enabled -- Connection mirroring ... Workaround ... Delete the affected flows and then cause them to be re-created. ... Disable HA mirroring.