BugZero found this defect 20 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/29/2024
F5OS
F5OS F5OS
F5OS-A 1.5.1
F5OS-A 1.5.2
F5OS-A 1.7.0
No fixed releases provided.
Bug ID 1492625: Tenant may misreport trunk status after multiple interfaces go down concurrently ... Last Modified: Apr 29, 2024 ... Symptoms ... On r2000-series and r4000-series appliances, if multiple external links in a trunk go down simultaneously, the trunk status may be reported incorrectly inside a BIG-IP tenant. - The system reports the trunk as "up", but with no available bandwidth. - The underlying interfaces are reported as down. - HA group score may not be correctly calculated (since the BIG-IP tenant reports the as "up") ... Impact ... Incorrect reporting of trunk state within the tenant. ... HA group failover based on the trunk may not occur as expected. ... Conditions ... - r2000-series or r4000-series appliance - Multiple external links in a trunk - Multiple interfaces are disabled or unplugged simultaneously This appears to be a relatively rare occurrence. ... Workaround ... None