Operational Defect Database

BugZero found this defect 67 days ago.

F5 | 1518997

Under extreme conditions (with full load) traffic fail over and TMM restart may happen due to internal Session DB malfunction

Last update date:

5/2/2024

Affected products:

BIG-IP

BIG-IP F5OS-C

Affected releases:

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1518997: Under extreme conditions (with full load) traffic fail over and TMM restart may happen due to internal Session DB malfunction ... Symptoms ... On a High capacity chassis system that is running at extreme load conditions with HA pair configuration, it is observed that occasionally a failover may happen due to an internal SessionDB malfunctioning. ... The system is handling about 40k+ connections in this state and is seen seldomly. ... This may lead to a TMM restart due to the ABORT situation due to looking up problems with sessionDB ... Running at extreme load conditons and handling 40k+ connections ... Workaround ... The system will recover by itself after reboot. ... But it may cause a disturbance to client traffic for a short duration while failover happens or TMM restart. ... Fix Information

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More