BugZero found this defect 65 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/30/2024
F5OS
F5OS F5OS-C
F5OS Velos
F5OS-C 1.6.0
F5OS-C 1.6.1
F5OS-C 1.6.2
No fixed releases provided.
Symptoms ... If a partition qkview is generated, a number of issues can subsequently occur if blades in the partition have not been rebooted: - If both system controllers are rebooted, backplane connectivity between the blades will fail, resulting in a complete loss of tenant connectivity. ... The system controllers do not need to be rebooted simultaneously. ... fpgamgr[14]: priority="Info" version=1.0 msgid=0x305000000000027 msg="VQF remote slot update" slot=4 ports="". - F5OS software will report incorrect link status for external interfaces if links change state. - The system may continue to treat interfaces configured as members of a LAG as being up even after the interface goes down, resulting in traffic failures. - Interfaces that were down at the point a partition Qkview was generated may fail to pass traffic properly even if the link comes up. ... Traffic will appear in a packet capture, but the system will not transmit egress traffic out the interface. ... Impact ... The EH...