SSL Orchestrator considers HA Invalid when using NTP auth servers

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP SSLO

Affected releases:

17.1.0

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

If HA remains invalid, select HA-Status for more details to correct. ... Any Configuration changes are not allowed until resolved" and going to the HA Status page it shows an error that an NTP server isn't set. ... Impact ... SSL Orchestrator becomes unusable with configuration changes being disabled. ... The workaround is to add localhost to the NTP server list. ... This way the NTP auth server will still be used, as the NTP requests sent to localhost will just be ignored. ... To add localhost to the server list use the following steps: 1. ... Verify ntp is working on the standby by running `ntpq -c as` and `ntpq -pn` 7. ... Perform a configsync to push the NTP change to the active 8. ... Verify ntp is working on the active by running `ntpq -c as` and `ntpq -pn`