BugZero found this defect 48 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
16.1.3
16.1.3.1
16.1.3.2
16.1.3.3
16.1.3.4
16.1.3.5
16.1.4
16.1.4.1
16.1.4.2
16.1.4.3
17.1.0
17.1.0.1
No fixed releases provided.
Bug Tracker ... ID 1572017 ... Bug ID 1572017: Unable to configure remote role group with "Log Manager" role. ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... BIG-IP TMOS(all modules) ... Known Affected Versions: ... Opened: Mar 26, 2024 ... Severity: 3-Major ... Fail to create new Remote Role Group object with "Log Manager" role. - GUI : Navigate to System >> Users : Remote Role Groups, press "Create" button, and set "Assigned Role" to "Log Manager". - CLI : tmsh modify auth remote-role { role-info add { /Common/my-logmanager-group { attribute F5-LTM-User-Role=90 console tmsh line-order 1 role logmanager user-partition All } Following error will be generated on /var/log/ltm. 01070920:3: Application error for confpp: remoterole role setting logmanager is invalid. ... Cannot configure Remote Role Group object with "Log Manager" role. ... Remote Role Group object with "Log Manager" role. ... None. Use other remote role groups than "Log Manager" (e.g., "Operator"). ... Fix ...