Operational Defect Database

BugZero found this defect 41 days ago.

F5 | 1575269

Cannot create a route-domain and modify VLAN MTU in a single transaction

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1575269: Cannot create a route-domain and modify VLAN MTU in a single transaction ... Last Modified: Apr 26, 2024 ... Config restore fails in the BIG-IP tenant while restoring from UCS. ... Impact ... When performing the change as a transaction, the transaction fails. ... When performing a config restore via a UCS load, config restore fails. ... Conditions ... -- Using tmsh transactions -- Setting the route domain and the MTU for a VLAN in a single transaction ... Workaround ... Before restoring, create the route-domain or modify the MTU setting ahead of time, and then load the UCS file. ... Fix Information

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More

Search:

...