4/26/2024
BIG-IP
BIG-IP TMOS
17.1.0.1
17.1.0.2
17.1.0.3
17.1.1
17.1.1.1
17.1.1.2
17.1.1.3
No fixed releases provided.
Bug ID 1575269: Cannot create a route-domain and modify VLAN MTU in a single transaction ... Last Modified: Apr 26, 2024 ... Config restore fails in the BIG-IP tenant while restoring from UCS. ... Impact ... When performing the change as a transaction, the transaction fails. ... When performing a config restore via a UCS load, config restore fails. ... Conditions ... -- Using tmsh transactions -- Setting the route domain and the MTU for a VLAN in a single transaction ... Workaround ... Before restoring, create the route-domain or modify the MTU setting ahead of time, and then load the UCS file. ... Fix Information