BugZero found this defect 19 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/30/2024
BIG-IP
BIG-IP APM
16.1.0
16.1.1
16.1.2
16.1.2.1
16.1.2.2
16.1.3
16.1.3.1
16.1.3.2
16.1.3.3
16.1.3.4
16.1.3.5
16.1.4
No fixed releases provided.
Severity: 3-Major ... Symptoms ... Adding too many settings to the single customization image leads to undefined behaviour. ... Following is an example: ^/public/images/customization//Common/<ap>_ap_general_ui/logo_ ^/public/images/customization//Common/<ap>_ap_general_ui/banner_ ^/public/images/customization/.+/(front|background|shrink(ed)?|expand(ed)?|separator|urlsame|urlnew|home|search_res|vdi_settings|banner|toolbar|contentpane|company|disconnect|warning|help|fw|logopopup|bannerpopup|toolbarpopup|cntpanelefthov|cntpanerighthov|cntpanemiddlehov|disconleft|disconright|disconmiddle|disconlefthov|disconrighthov|disconmiddlehov|disconnected|connected|waiting|sprites|side|logout|page|logo|go|image([0-9]{1,2})?)_.+ ... ^/public/advanced/images//Common/<ap>/image[0-9]{2}\.(gif|png|jpg|jpeg)$ ... Impact ... Incorrect parsing of the Access Profile: Customization fields lead TMM Core event and triggered a Failover. ... Conditions ... Parsing of access profile. ... Workaround ... None