The zrd exits on error from bind about .jnl file error

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP DNS

BIG-IP GTM

Affected releases:

10.2.4

11.2.0

11.2.1

11.4.0

11.4.1

11.5.0

11.5.1

11.5.2

11.5.3

11.5.4

11.5.5

11.5.6

Fixed releases:

No fixed releases provided.

Description:

The zrd process exits and cannot be restarted. ... Impact ... The zrd process cannot be restarted. ... This issue occurs when the journal is out-of-sync with the zone. ... Workaround ... Ensure that no one else is making configuration changes, it is recommended to make changes making changes during a maintenance window. ... On a working system, perform the following steps: 1. ... Run command # rndc freeze $z (Do this for all nonworking zones. ... Do not perform the thaw until you finish copying all reuqired files to the nonworking system.) 2. ... Run command # tar zcvf /tmp/named.zone.files namedb/db.[nonworking zones]. ... Repeat these steps until all previously non-working systems are working.