5/17/2024
BIG-IP
BIG-IP DNS
BIG-IP GTM
10.2.4
11.2.0
11.2.1
11.4.0
11.4.1
11.5.0
11.5.1
11.5.2
11.5.3
11.5.4
11.5.5
11.5.6
No fixed releases provided.
The zrd process exits and cannot be restarted. ... Impact ... The zrd process cannot be restarted. ... This issue occurs when the journal is out-of-sync with the zone. ... Workaround ... Ensure that no one else is making configuration changes, it is recommended to make changes making changes during a maintenance window. ... On a working system, perform the following steps: 1. ... Run command # rndc freeze $z (Do this for all nonworking zones. ... Do not perform the thaw until you finish copying all reuqired files to the nonworking system.) 2. ... Run command # tar zcvf /tmp/named.zone.files namedb/db.[nonworking zones]. ... Repeat these steps until all previously non-working systems are working.