BugZero found this defect 2215 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/17/2024
BIG-IP
BIG-IP AVR
11.6.0
12.1.0 HF1
12.1.0 HF2
12.1.1 HF1
12.1.1 HF2
12.1.2 HF1
12.1.2 HF2
12.0.0
11.6.1
11.5.4 HF3
Severity: 3-Major ... Symptoms ... When there is a lot of information in URL Latencies with paging being available for more than 180 pages, no data is being displayed when switching to any of the pages above 180 ... Impact ... Not all URLs will be visible ... URLs count exceeds 1800 ... Workaround ... Filtering can be used to limit the number of results below 1800. ... Fix Information ... Number of reported URLs is now limited to 1000 (100 pages), consistent with other reporting pages. ... Behavior Change