Operational Defect Database

BugZero found this defect 2215 days ago.

F5 | 530505

IP fragments can cause TMM to crash when packet filtering is enabled

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

11.6.0

11.5.3

11.5.2

11.5.1

11.5.1

11.5.1

11.5.1

11.5.1

11.4.1

11.2.1

10.2.4

10.2.4

Fixed releases:

12.0.0

11.6.1

11.5.4

11.4.1 HF10

Description:

Bug ID 530505: IP fragments can cause TMM to crash when packet filtering is enabled ... Symptoms ... TMM can crash when an IP fragment is received and packet filtering is enabled. ... Impact ... Conditions ... This issue can occur when packet filtering is enabled and an IP fragment is received on the non-owning TMM. ... To determine if packet filtering is enabled, then the packetfilter setting can be queried by using the 'tmsh list sys db packetfilter' command. ... Workaround ... Fix Information ... When packet filtering is enabled and an IP fragment is received on the non-owning TMM, TMM forwards the IP fragment without issue. ... Behavior Change