4/26/2024
BIG-IP
BIG-IP All
11.6.0
11.6.1
11.6.2
11.6.3
11.6.3.1
11.6.3.2
11.6.3.3
11.6.3.4
11.6.4
11.6.5
11.6.5.1
11.6.5.2
No fixed releases provided.
Bug ID 563144: Changing the system's admin user causes many errors in the REST framework. ... Last Modified: Apr 26, 2024 ... Symptoms ... The iControl REST log at /var/log/icrd will have entries similar to the following: notice icrd_child[32206]: 01420003:5: Cannot load user credentials for user "admin" Current session has been terminated. ... Impact ... Many REST APIs do not function, and functionality that depends on REST fails. ... Conditions ... Change the default admin user, for example, by following the steps in the Article K15632: Disabling the admin and root accounts using the BIG-IP Configuration utility or the Traffic Management Shell: https://support.f5.com/csp/article/K15632. ... There is no workaround. ... You must use the default admin in order for iControl REST calls to work. ... Fix Information