BIG-IP
BIG-IP AVR
11.5.1 HF2
11.5.1 HF3
11.5.1 HF4
11.5.1 HF5
11.5.1 HF6
11.5.1 HF7
11.5.1 HF8
11.5.1 HF9
11.5.1 HF10
11.5.1 HF11
11.5.2 HF1
11.5.3 HF1
12.1.0
11.6.1 HF2
11.5.4 HF3
Severity: 3-Major ... Symptoms ... When non cumulative metrics are selected for an Alert on a dimension that's other than a Virtual Server, errors appear in the log. ... Impact ... You are able to configure invalid alerts but no warning is given and the metric does not work and generates errors in the /var/log/monpd.log file. ... Conditions ... Analytics in use, and non-cumulative metrics such as the following are used on a time dimension: - Maximum TPS - Maximum Server Latency - Maximum Page Load Time - Maximum Request Throughput - Maximum Response Throughput ... Fix Information ... Invalid combination of entities for Alerts setup is no longer allowed. ... Validation is present both on UI side and the backend. ... Behavior Change