Operational Defect Database

BugZero found this defect 2125 days ago.

F5 | 600492

NTLMv2 WebSSO to backend fails if username contains Greek small letter final sigma (?)

Last update date:

5/18/2024

Affected products:

BIG-IP

BIG-IP APM

Affected releases:

13.0.0

13.0.0 HF1

13.0.0 HF2

13.0.0 HF3

13.0.1

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

Fixed releases:

No fixed releases provided.

Description:

Severity: 4-Minor ... Symptoms ... NTLMv2 WebSSO to backend fails if username contains Greek small letter final sigma (?) ... Impact ... User with Greek small final sigma in the username cannot logon automatically to the RDP backend. ... Conditions ... Non-ASCII username containing Greek letter ? (http://www.charbase.com/03c2-unicode-greek-small-letter-final-sigma) causes SSO to the backend to fail. ... Workaround ... User has to re-enter credentials again manually. ... Fix Information ... None