12.1.3
Bug ID 604011: Sync fails when iRule or policy is in use ... Last Modified: May 17, 2024 ... Symptoms ... After upgrading and attempting to sync to devices in a sync group, sync fails with the following error: Load failed from 119.big.ip 01070621:3: Rule priorities for virtual server (vs1) must be unique. ... Load failed from /Common/big152 01070712:3: Caught configuration exception (0), Values (/Common/vs1) specified for virtual server policy (/Common/vs1 /Common/asm_auto_l7_policy__vs1): foreign key index (vs_FK) do not point at an item that exists in the database. ... Conditions ... - A virtual address exists in the traffic-group-local-only group, meaning that it is not synced - A CPM policy or iRule is applied to that virtual server - Conduct a sync This was seen on an upgrade from 12.0.0 to 12.1.0 HF1 or beyond, but could be triggered on an upgrade from any version from 11.4.0 and beyond to 12.1.0 HF1. ... Workaround ... Disassociate the iRule or policy from the virtual server,...