BugZero found this defect 2215 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP MA-VE
13.0.0
13.0.0 HF1
13.0.0 HF2
13.0.0 HF3
13.0.1
13.1.0
13.1.0.1
13.1.0.2
13.1.0.3
13.1.0.4
13.1.0.5
13.1.0.6
No fixed releases provided.
Bug ID 657459: Single-NIC BIG-IP VE may erroneously revert to the default management httpd port after a configuration reload ... Last Modified: Apr 26, 2024 ... Symptoms ... The single Network Interface Card (NIC) BIG-IP Virtual Edition (VE) may erroneously revert to the default management httpd port after you reload the configuration. ... Impact ... Management traffic port will revert to 8443 after any action which reloads configuration. ... Conditions ... Management traffic port has been set to port 443 instead of the default port 8443. ... Workaround ... Reconfigure port after each configuration reload using the following command: modify sys httpd ssl-port 443. ... Fix Information