Operational Defect Database

BugZero found this defect 2215 days ago.

F5 | 658943

Errors when platform migration process is loading UCS using trunks on vCMP guest/F5OS Tenants

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

12.1.0

12.1.1

12.1.2

12.1.3

12.1.3.1

12.1.3.2

12.1.3.3

12.1.3.4

12.1.3.5

12.1.3.6

12.1.3.7

12.1.4

Fixed releases:

14.1.4.1

Description:

Bug ID 658943: Errors when platform migration process is loading UCS using trunks on vCMP guest/F5OS Tenants ... Symptoms ... During the platform migration from a physical BIG-IP system to a BIG-IP vCMP guest/F5OS Tenant, the load fails with one of the following messages: 01070687:3: Link Aggregation Control Protocol (LACP) is not supported on this platform. ... Unexpected Error: Loading configuration process failed. ... Impact ... The platform migration fails and the configuration does not load. ... Conditions ... -- The source device is a physical BIG-IP device with one or more trunks with or without LACP in its configuration. -- The destination device is a vCMP guest/F5OS Tenant. ... Workaround ... You can use one of the following workarounds: -- Remove all trunks from the source configuration prior to generation of the UCS. -- Before loading the UCS archive onto the target BIG-IP, edit the archive and remove the trunk configuration from ./config/bigip_base.conf, and then repack ...