BugZero found this defect 2215 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
12.1.0
12.1.1
12.1.2
12.1.3
12.1.3.1
12.1.3.2
12.1.3.3
12.1.3.4
12.1.3.5
12.1.3.6
12.1.3.7
12.1.4
14.1.4.1
Bug ID 658943: Errors when platform migration process is loading UCS using trunks on vCMP guest/F5OS Tenants ... Symptoms ... During the platform migration from a physical BIG-IP system to a BIG-IP vCMP guest/F5OS Tenant, the load fails with one of the following messages: 01070687:3: Link Aggregation Control Protocol (LACP) is not supported on this platform. ... Unexpected Error: Loading configuration process failed. ... Impact ... The platform migration fails and the configuration does not load. ... Conditions ... -- The source device is a physical BIG-IP device with one or more trunks with or without LACP in its configuration. -- The destination device is a vCMP guest/F5OS Tenant. ... Workaround ... You can use one of the following workarounds: -- Remove all trunks from the source configuration prior to generation of the UCS. -- Before loading the UCS archive onto the target BIG-IP, edit the archive and remove the trunk configuration from ./config/bigip_base.conf, and then repack ...