Operational Defect Database

BugZero found this defect 2215 days ago.

F5 | 696363

Unable to create SNMP trap in the GUI

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

12.1.2

12.1.3

12.1.3.1

12.1.3.2

12.1.3.3

12.1.3.4

12.1.3.5

12.1.3.6

12.1.3.7

12.1.4

12.1.4.1

12.1.5

Fixed releases:

No fixed releases provided.

Description:

Symptoms ... Trying to create a SNMP trap may fail in the GUI with the following error message: An error has occurred while trying to process your request. ... Impact ... GUI parameter checking does not work as expected. ... BIG-IP Administrator is unable to create a SNMP trap session. ... -- Trap destinations are configured using the GUI: When trap destinations are configured in the GUI, the trap name is generated using the destination IP address. -- Traps of the same destination address were previously created and deleted. ... Workaround ... To work around this issue when using the GUI, remove all traps that have the same destination address as the new one that failed. ... Then re-add your destination. ... Tip: You can use tmsh to create/delete/modify SNMP traps, which enables viewing of the generated names, making it easier to understand what error has occurred. ... Fix Information

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More