BugZero found this defect 1560 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/17/2024
BIG-IP
BIG-IP TMOS
13.1.0
13.1.0.1
13.1.0.2
13.1.0.3
13.1.0.4
13.1.0.5
13.1.0.6
13.1.0.7
13.1.0.8
13.1.1
13.1.1.2
13.1.1.3
16.1.0
16.0.1
15.1.1
14.1.2.8
13.1.3.5
-- The UCS configuration is not applied. -- The BIG-IP is not in a fully operational state. ... Conditions ... - Restoring configuration from UCS. - The UCS is being restored on a different BIG-IP system with a different master key. ... Workaround ... If you encounter this error and dynad is not in use (dynamic debug) you can manually edit bigip_base.conf. ... 1. Locate the dynad config in /config/bigip_base.conf file: For example, the dynad config will look like: sys dynad key { key $M$jV$VX7HMp5q346nsTYDYFPnYdJLrBPyQSCrDTJYAz4je7KXJAC38fxtDJL35KtF66bq } 2. ... Modify the dynad configuration lines to: sys dynad key { key "test" } 3, Save the updated bigip_base.conf file 4. ... Load the configuration with command: tmsh load sys config ... Fix Information ... The log message is improved to provide the BIG-IP administrator with more specific detail that the dynad key failed to be decrypted. ... Behavior Change