F5 | 714176

UCS restore may fail with: Decryption of the field (privatekey) for object (9717) failed

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

13.1.0.7

13.1.0.8

13.1.1

13.1.1.2

13.1.1.3

Fixed releases:

16.1.0

16.0.1

15.1.1

14.1.2.8

13.1.3.5

Description:

-- The UCS configuration is not applied. -- The BIG-IP is not in a fully operational state. ... Conditions ... - Restoring configuration from UCS. - The UCS is being restored on a different BIG-IP system with a different master key. ... Workaround ... If you encounter this error and dynad is not in use (dynamic debug) you can manually edit bigip_base.conf. ... 1. Locate the dynad config in /config/bigip_base.conf file: For example, the dynad config will look like: sys dynad key { key $M$jV$VX7HMp5q346nsTYDYFPnYdJLrBPyQSCrDTJYAz4je7KXJAC38fxtDJL35KtF66bq } 2. ... Modify the dynad configuration lines to: sys dynad key { key "test" } 3, Save the updated bigip_base.conf file 4. ... Load the configuration with command: tmsh load sys config ... Fix Information ... The log message is improved to provide the BIG-IP administrator with more specific detail that the dynad key failed to be decrypted. ... Behavior Change