Operational Defect Database

BugZero found this defect 1285 days ago.

F5 | 722657

Mcpd and bigd monitor states are getting out-of-sync intermittently

Last update date:

5/14/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

12.0.0

12.0.0 HF1

12.1.0 HF1

12.0.0 HF2

12.1.0 HF2

12.0.0 HF3

12.0.0 HF4

12.1.1 HF1

12.1.1 HF2

12.1.2 HF1

12.1.2 HF2

12.1.0

Fixed releases:

No fixed releases provided.

Description:

Bug ID 722657: Mcpd and bigd monitor states are getting out-of-sync intermittently ... Last Modified: May 14, 2024 ... Severity: 3-Major ... Symptoms ... Currently, bigd only informs mcpd of the state of a node on a state change. ... If the pool member status happens to be incorrect, this can cause the following symptoms. -- Pool member status may be incorrect for a long time -- Traffic may be directed to a pool member that is actually down. ... Impact ... -- False monitor status in UI/CLI. -- Large number of RST connections as traffic is directed to a pool member that is actually DOWN ... Conditions ... -- Monitor is attached to pool member and bigd does not inform the state change event for a long time in some of the corner cases. -- No periodic events from bigd to mcpd. ... Workaround

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Test

Learn More