BugZero found this defect 1285 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/14/2024
BIG-IP
BIG-IP LTM
12.0.0
12.0.0 HF1
12.1.0 HF1
12.0.0 HF2
12.1.0 HF2
12.0.0 HF3
12.0.0 HF4
12.1.1 HF1
12.1.1 HF2
12.1.2 HF1
12.1.2 HF2
12.1.0
No fixed releases provided.
Bug ID 722657: Mcpd and bigd monitor states are getting out-of-sync intermittently ... Last Modified: May 14, 2024 ... Severity: 3-Major ... Symptoms ... Currently, bigd only informs mcpd of the state of a node on a state change. ... If the pool member status happens to be incorrect, this can cause the following symptoms. -- Pool member status may be incorrect for a long time -- Traffic may be directed to a pool member that is actually down. ... Impact ... -- False monitor status in UI/CLI. -- Large number of RST connections as traffic is directed to a pool member that is actually DOWN ... Conditions ... -- Monitor is attached to pool member and bigd does not inform the state change event for a long time in some of the corner cases. -- No periodic events from bigd to mcpd. ... Workaround