BugZero found this defect 1252 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP LTM
12.1.0
12.1.1
12.1.2
12.1.3
12.1.3.1
12.1.3.2
12.1.3.3
12.1.3.4
12.1.3.5
12.1.3.6
12.1.3.7
12.1.4
No fixed releases provided.
Bug ID 742764: If two racoon daemon are spawned on startup, one fails and cores. ... Last Modified: Apr 26, 2024 ... Symptoms ... When a BIG-IP system becomes Active, tmipsecd starts a racoon daemon for each route domain, including the default RD 0. ... If for any reason racoon fails to fully start, tmipsecd will start another instance of racoon. ... When this occurs, one or both of them may crash and create a core file. ... Impact ... IPsec IKEv1 tunnels might delay starting while racoon restarts. ... Conditions ... -- BIG-IP becomes Active or racoon is (re)started. -- IPsec does not have to be configured for this failure to occur. ... Workaround