Diameter iAppLX Config Wizard should creates a new router by default

Last update date:

5/18/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

15.0.0

15.0.1

15.0.1.1

15.0.1.2

15.0.1.3

15.0.1.4

Fixed releases:

15.1.0

Description:

Changes made to the router profile have no effect. ... Impact ... The virtual server created by the Diameter iAppLX Config Wizard uses the default router profile, when it should create a new one instead. ... Changes made to the router profile have no effect because it's not used by the virtual server. ... Conditions ... This occurs when a Diameter MRF configuration is created by the Diameter iAppLX config wizard. ... Workaround ... Manually alter the configuration with tmsh or by editing the config file to used the non-default router profile. ... Fix Information ... The non-default diameter router profile created by the Diameter iAppLX Configuration Wizard is now automatically assigned to the virtual server by the iAppLX.