Operational Defect Database

BugZero found this defect 1997 days ago.

F5 | 751540

GTM Sync group not syncing properly with multiple self IP addresses configured on one VLAN but not all configured for GTM server

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP DNS

BIG-IP GTM

Affected releases:

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

13.1.0.7

13.1.0.8

13.1.1

13.1.1.2

13.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 751540: GTM Sync group not syncing properly with multiple self IP addresses configured on one VLAN but not all configured for GTM server ... Last Modified: Apr 26, 2024 ... Affected Product(s): ... Severity: 3-Major ... Symptoms ... GTM changes in some devices are not synced to other GTM-configured devices in the same syncgroup. ... Impact ... GTM Sync group not syncing properly. ... Workaround ... Configure all self IP addresses in the syncgroup for GTM server. ... Fix Information