Operational Defect Database

BugZero found this defect 1880 days ago.

F5 | 758929

Bcm56xxd MIIM bus access failure

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

12.1.4

12.1.4.1

12.1.5

12.1.5.1

12.1.5.2

12.1.5.3

12.1.6

13.0.0

13.0.0 HF1

13.0.0 HF2

13.0.0 HF3

13.0.1

Fixed releases:

No fixed releases provided.

Description:

Severity: 2-Critical ... Symptoms ... Bcm56xxd daemon running on certain BIG-IP devices might experience MIIM bus access failure. ... The system posts a message similar to the following in the ltm log: info bcm56xxd: 012c0016:6: MiimTimeOut:soc_miim_write, timeout (id=0xc9 addr=0x1f data=0x0000) ... Impact ... The affected BIG-IP system fails to pass traffic. ... If configured for high availability (HA) and the HA connection has not been disrupted, failover occurs. ... Conditions ... Using one of the following platforms: + VIPRION B2250 Blade (A112) + VIPRION B2150 Blade (A113) + VIPRION B4300 Blade (A108) + BIG-IP 5250v + BIG-IP 7200S + BIG-IP i5600 + BIG-IP i5820 + BIG-IP i7800 + BIG-IP i10800