4/26/2024
BIG-IP
BIG-IP LTM
14.0.0
14.0.0.1
14.0.0.2
14.0.0.3
14.0.0.4
14.0.0.5
14.0.1
14.0.1.1
14.1.0
14.1.0.1
14.1.0.2
14.1.0.3
No fixed releases provided.
Severity: 4-Minor ... Symptoms ... You are using a virtual with an ilx profile generated from an iRules LX Streaming extension and observed the following error or similar. ... Sep 05 09:16:52 pid[5850] Error: Uncaught, unspecified "error" event. ... (ETIMEDOUT) Sep 05 09:16:52 pid[5850] at ILXFlow.emit (events.js:163:17) ... Impact ... Traffic may be disrupted until the sdmd daemon has respawned another node.js process. ... Conditions ... Virtual server with an ilx profile generated from an iRules LX Streaming extension. ... The problem is aggravated if a web-acceleration profile is configured. ... Workaround