Operational Defect Database

BugZero found this defect 1657 days ago.

F5 | 841649

Hardware accelerated connection mismatch resulting in tmm core

Last update date:

5/17/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

13.1.1

13.1.1.2

13.1.1.3

13.1.1.4

13.1.1.5

13.1.3

13.1.3.1

13.1.3.2

13.1.3.3

13.1.3.4

13.1.3.5

13.1.3.6

Fixed releases:

16.0.0

15.1.2

14.1.4.1

Description:

Bug ID 841649: Hardware accelerated connection mismatch resulting in tmm core ... Last Modified: May 17, 2024 ... Severity: 3-Major ... Symptoms ... Tmm receives an update from the ePVA for a hardware accelerated connection that is matched to the wrong correction. ... This can result in a tmm core, which is reported as a segment fault in the tmm log files. ... Impact ... Traffic disrupted while tmm restarts. ... Conditions ... One or more of the following: -- A FastL4 virtual server that has hardware acceleration enabled. -- A NAT or SNAT object without a virtual server. ... Workaround

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Verified

Learn More

Search:

...