Scriptd coring while running f5.automated_backup script

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

12.1.0

12.1.1

12.1.2

12.1.3

12.1.3.1

12.1.3.2

12.1.3.3

12.1.3.4

12.1.3.5

12.1.3.6

12.1.3.7

12.1.4

Fixed releases:

No fixed releases provided.

Description:

Scriptd core. ... Conditions ... Configure the iApp application with f5.automated_backup template to do auto-backup at regular intervals. ... Workaround ... Increasing the sys scriptd max-script-run-time higher then the default of 300 seconds might be helpful if the higher timeout allows the script to complete. ... For example, if the script is saving a UCS and the save takes 400 seconds, then increasing the max-script-run-time to 430 seconds would allow the script to finish and would work around this issue. ... Fix Information ... None