Operational Defect Database

BugZero found this defect 1137 days ago.

F5 | 851837

Mcpd fails to start for single NIC VE devices configured in a trust domain

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

12.1.5

12.1.5.1

12.1.5.2

12.1.5.3

12.1.6

13.0.0

13.0.0 HF1

13.0.0 HF2

13.0.0 HF3

13.0.1

13.1.0

13.1.0.1

Fixed releases:

No fixed releases provided.

Description:

Bug ID 851837: Mcpd fails to start for single NIC VE devices configured in a trust domain ... Impact ... The mcpd process fails to start, and the configuration does not load. ... Conditions ... Workaround ... Manually copy and paste the self IP configuration snippet into the /config/bigip_base.conf file: 1. ... Connect to the CLI. ... Save the changes and exit. ... 4. Load the configuration using the command: tmsh load sys config 5. ... If APM or ASM is provisioned/configured, then also restart services with this command: bigstart restart ... Fix Information