Operational Defect Database

BugZero found this defect 1074 days ago.

F5 | 873349

Mac Edge Client fails to establish a VPN connection on non-standard port in load balancing setup

Last update date:

4/25/2024

Affected products:

APM-Clients

APM-Clients APM

Affected releases:

7.1.9

7.1.9.7

7.1.9.8

7.1.9.9

Fixed releases:

7.2.2

Description:

Bug ID 873349: Mac Edge Client fails to establish a VPN connection on non-standard port in load balancing setup ... Last Modified: Apr 25, 2024 ... If BIG-IP LTM and APM Network Access VPN systems use different ports, then the Mac Edge Client fails to establish a VPN. Mac Edge Client uses APM VPN virtual server port for the VPN connection instead of LTM one. ... Impact ... Mac Edge Client fails to establish a VPN connection if APM Network Access systems use different port than the BIG-IP LTM system. ... Conditions ... Mac Edge Client fails to establish a VPN connection if following conditions are met: - Connection is made through load balancing LTM virtual server (or another router/firewall device); - APM Network Access VPN virtual server is configured on different port than LTM virtual server. ... Workaround ... Fix Information ... Now the Mac Edge Client can successfully establish a VPN tunnel in load balancing setup, even if LTM and APM systems use different ports for the virtual...

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Verified

Learn More

Search:

...