4/26/2024
BIG-IP
BIG-IP ASM
BIG-IP Install/Upgrade
12.1.5
12.1.5.1
12.1.5.2
12.1.5.3
12.1.6
13.0.0
13.0.0 HF1
13.0.0 HF2
13.0.0 HF3
13.0.1
13.1.0
13.1.0.1
No fixed releases provided.
Bug ID 887265: BIG-IP systems may fail to come online after upgrade with ASM and VLAN-failsafe configuration ... Last Modified: Apr 26, 2024 ... Severity: 3-Major ... Symptoms ... When booting to a boot location for the first time, the system does not come on-line. ... Impact ... BIG-IP processes continually restart (VLAN failsafe-action failover-restart-tm), or the BIG-IP system continually reboots (VLAN failsafe-action reboot) ... -- There is a large configuration. -- VLAN failsafe is configured, and the failsafe-action is something other than failover. -- The BIG-IP system is an appliance. ... Workaround ... Either disable VLAN failsafe or set the failsafe-action to failover during an upgrade. ... Fix Information ... None