Operational Defect Database

BugZero found this defect 1483 days ago.

F5 | 887265

BIG-IP systems may fail to come online after upgrade with ASM and VLAN-failsafe configuration

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP ASM

BIG-IP Install/Upgrade

Affected releases:

12.1.5

12.1.5.1

12.1.5.2

12.1.5.3

12.1.6

13.0.0

13.0.0 HF1

13.0.0 HF2

13.0.0 HF3

13.0.1

13.1.0

13.1.0.1

Fixed releases:

No fixed releases provided.

Description:

Bug ID 887265: BIG-IP systems may fail to come online after upgrade with ASM and VLAN-failsafe configuration ... Last Modified: Apr 26, 2024 ... Severity: 3-Major ... Symptoms ... When booting to a boot location for the first time, the system does not come on-line. ... Impact ... BIG-IP processes continually restart (VLAN failsafe-action failover-restart-tm), or the BIG-IP system continually reboots (VLAN failsafe-action reboot) ... -- There is a large configuration. -- VLAN failsafe is configured, and the failsafe-action is something other than failover. -- The BIG-IP system is an appliance. ... Workaround ... Either disable VLAN failsafe or set the failsafe-action to failover during an upgrade. ... Fix Information ... None

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More

Search:

...