BugZero found this defect 830 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
5/4/2024
BIG-IP
BIG-IP All
10.2.1
10.2.2
10.2.3
10.2.4
11.3.0
11.4.1
11.5.0
11.5.1
11.5.2
11.5.3
11.5.4
11.5.5
No fixed releases provided.
Bug ID 891333: The HSB on BIG-IP platforms can get into a bad state resulting in packet corruption. ... Networking connectivity issues, such as ARP resolution issues, high availability (HA) failures, health monitor instability, etc. Packet captures with Wireshark or tshark can be used to show bit-errors/corruption in the network packet for traffic passing through the HSB. ... This corruption can occur in various parts of the packet such as the MAC address, EtherType, packet checksums, etc. ... Impact ... Network connectivity problems on some traffic passing through the affected HSB. Could be reflected in the status of Config Sync or more health monitors down on one member of HA pair. ... Conditions ... Reboot the affected device. ... If a reboot does not resolve the issue, then its most likely a hardware issue. ... Please work with Support on a RMA. ... F5 has introduced a detection mechanism in newer versions of code. ... Please refer to the following document for more details: htt...