Operational Defect Database

BugZero found this defect 1063 days ago.

F5 | 895669

VCMP host does not validate when an unsupported TurboFlex profile is configured

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP LTM

Affected releases:

12.1.0

12.1.1

12.1.2

12.1.3

12.1.3.1

12.1.3.2

12.1.3.3

12.1.3.4

12.1.3.5

12.1.3.6

12.1.3.7

12.1.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 895669: VCMP host does not validate when an unsupported TurboFlex profile is configured ... Last Modified: Apr 26, 2024 ... Severity: 4-Minor ... Symptoms ... There is no validation error for when unsupported TurboFlex profiles are configured on vCMP hosts for relevant platforms. ... Due to this lack of validation, it can result in incorrect FPGA firmware being loaded on the host and thus a guest may fail to start or reboot constantly. ... Impact ... Incorrect FPGA firmware is loaded on the host, which can cause problems with the data plane on the guest. ... Conditions ... (1) Provision vCMP on the host and deploy 2x guests with 4 cores (2) On the vCMP host, manually change TurboFlex profile type to be one that it does not support. ... Workaround

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More