4/26/2024
BIG-IP
BIG-IP LTM
13.0.0
13.0.0 HF1
13.0.0 HF2
13.0.0 HF3
13.0.1
13.1.0
13.1.0.1
13.1.0.2
13.1.0.3
13.1.0.4
13.1.0.5
13.1.0.6
No fixed releases provided.
Bug ID 905477: The sdmd daemon cores during config sync when multiple devices configured for iRules LX ... The iRules LX workspaces belong on only one device in a Device Service Cluster (DSC). ... If you have the same iRules LX workspace configured on multiple devices and then perform a config sync operation, the sdmd daemon cores. ... Impact ... The sdmd daemon cores. ... Although having multiple devices configured with the same iRules LX workspace is an incorrect configuration, sdmd should not core. ... Conditions ... -- Multiple devices configured with the same iRules LX workspace in a DSC. -- Change one of the devices such that the configuration requires a config sync. -- Perform the config sync. ... Workaround ... When the iRules LX workspace is correctly configured, i.e., on only one device in a DSC, there is no need to config sync, so this issues does not occur. ... Fix Information