Operational Defect Database

BugZero found this defect 423 days ago.

F5 | 908005

Limit on log framework configuration size

Last update date:

5/15/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

12.1.3

12.1.3.1

12.1.3.2

12.1.3.3

12.1.3.4

12.1.3.5

12.1.3.6

12.1.3.7

12.1.4

12.1.4.1

12.1.5

12.1.5.1

Fixed releases:

No fixed releases provided.

Description:

While the system config is loading, you see numerous error messages: -- err errdefsd[26475]: 01940010:3: errdefs: failed to add splunk destination. -- err errdefsd[585]: 01940015:3: errdefs: failure publishing errdefs configuration. ... Impact ... System does not log as expected. ... Conditions ... This can occur during a log-config update/load that has numerous log-config objects configured. ... Workaround ... None