Operational Defect Database

BugZero found this defect 1410 days ago.

F5 | 920817

Wide IP operations performed in quick succession result in missing resource records and out of sync journals.

Last update date:

4/25/2024

Affected products:

BIG-IP

BIG-IP DNS

BIG-IP GTM

BIG-IP TMOS

Affected releases:

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

13.1.0.7

13.1.0.8

13.1.1

13.1.1.2

13.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Bug ID 920817: Wide IP operations performed in quick succession result in missing resource records and out of sync journals. ... Two issues occur with Wide IP operations performed in quick succession: 1. ... DNS Zone syncing is missing resource records. ... 2. In some cases it throws named/zrd error: journal rollforward failed: journal out of sync with zone. ... DNS resource records can be missing from the BIND DNS database. ... The impact of this issue is that if GSLB Load Balancing falls back to BIND, the DNS resource records may not be present. ... Manually remove the .jnl files in order to restore named/zrd on all GTMs. ... Conditions ... This issue can occur when a large number of configuration changes, including Wide IP changes, are made simultaneously on multiple GTM/DNS devices in a sync group. ... Note: It is also possible to turn off zone syncing. ... GTM/DNS configuration is still synced, but you lose the ability to sync non-Wide IP changes to the BIND DB. ... If you do n...

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

New

Learn More