F5 | 922053

inaccurate number of trunk members reported by bcm56xxd/bcmLINK

Last update date:

5/14/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.0.0

15.0.1

15.0.1.1

15.0.1.2

15.0.1.3

15.0.1.4

15.1.0

15.1.0.1

15.1.0.2

15.1.0.3

15.1.0.4

15.1.0.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 922053: inaccurate number of trunk members reported by bcm56xxd/bcmLINK ... Last Modified: May 14, 2024 ... Affected Product(s): ... Symptoms ... The "bcmLINK" process (sometimes referred to as "bcm56xxd") may fail with a segmentation fault and be restarted, leaving behind a core-dump file for "bcmLINK". ... An error message may be logged about the condition "max_mbrs > 0". ... Impact ... Momentary disruption of traffic handling by TMM. ... Conditions ... -- occurs in multi-blade VIPRION system with trunked interfaces -- precise trigger is not known ... Workaround