BugZero found this defect 1400 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/26/2024
BIG-IP
BIG-IP TMOS
12.1.5
12.1.5.1
12.1.5.2
12.1.5.3
12.1.6
13.0.0
13.0.0 HF1
13.0.0 HF2
13.0.0 HF3
13.0.1
13.1.0
13.1.0.1
No fixed releases provided.
Bug ID 928389: GUI becomes inaccessible after importing certificate under import type 'certificate' ... Last Modified: Apr 26, 2024 ... Symptoms ... After importing a new certificate, httpd goes down and the GUI becomes inaccessible. ... Impact ... The GUI is inaccessible as soon as you import a new device certificate using import-type 'Certificate'. ... Conditions ... Upload new certificate using Import-type 'Certificate' option. ... Workaround ... Manually copy the matching key to /config/httpd/conf/ssl.key/server.key and restart apache (bigstart restart httpd) If you do not have the matching key, generate a new key/cert pair from the command line by following K9114 ... Fix Information