Operational Defect Database

BugZero found this defect 1305 days ago.

F5 | 955897

Configuration may fail to load with named virtual-address for 0.0.0.0 in a non-zero route domain

Last update date:

5/10/2024

Affected products:

BIG-IP

BIG-IP Install/Upgrade

BIG-IP TMOS

Affected releases:

14.1.2.8

14.1.3

14.1.3.1

14.1.4

14.1.4.1

14.1.4.2

14.1.4.3

14.1.4.4

14.1.4.5

14.1.4.6

14.1.5

14.1.5.1

Fixed releases:

No fixed releases provided.

Description:

Bug ID 955897: Configuration may fail to load with named virtual-address for 0.0.0.0 in a non-zero route domain ... Last Modified: May 10, 2024 ... When reading the configuration from /config files, the BIG-IP system may fail to load the configuration regarding a virtual server with a named virtual-address for address 0.0.0.0 in a non-default route domain: err mcpd[21812]: 0107028b:3: The source (0.0.0.0%123) and destination (0.0.0.0) addresses for virtual server (/Common/vs1) must be in the same route domain. ... The configuration fails to load from disk when the affected objects do not yet exist in running memory or binary cache, for example, during: - Reinstalling - Upgrading - Loading manual changes to the /config/*.conf files - MCP force-reload Other operations such as rebooting, relicensing, and reloading the same configuration (such as 'tmsh load sys config' are not affected. ... Conditions ... The IPv6 address :: (or the keyword 'any6') is not affected. -- The virtual-addres...