4/26/2024
BIG-IP
BIG-IP LTM
15.1.0
15.1.0.1
15.1.0.2
15.1.0.3
15.1.0.4
15.1.0.5
15.1.1
15.1.2
15.1.2.1
15.1.3
15.1.3.1
15.1.4
No fixed releases provided.
Severity: 3-Major ... Symptoms ... HTTPS pool members are marked down when they are up. ... Impact ... Pool members are marked down because bigd cannot connect to the pool member using the Safenet HSM key. ... Conditions ... -- SafeNet HSM configured -- HTTPS monitor uses the safenet keys -- The key handle generated by the HSM is 0 ... Workaround ... Use in-TMM monitors as an alternative to bigd monitors. ... Fix Information ... None