Operational Defect Database

BugZero found this defect 1105 days ago.

F5 | 966729

LDAP system authentication does not support multiple servers

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP Install/Upgrade

BIG-IP TMOS

Affected releases:

14.1.0

14.1.0.1

14.1.0.2

14.1.0.3

14.1.0.5

14.1.0.6

14.1.2

14.1.2.1

14.1.2.2

14.1.2.3

14.1.2.4

14.1.2.5

Fixed releases:

No fixed releases provided.

Description:

Bug ID 966729: LDAP system authentication does not support multiple servers ... Symptoms ... On versions earlier than v14.1.0, the menu System :: Users :: Authentication allowed specifying multiple LDAP servers by separating multiple server IP addresses with commas. ... After upgrade to v14.1.0, the comma-separated values are not parsed correctly. ... This can render inoperative remote system authentication. ... Impact ... System authentication by remote servers is not operational after upgrade to v14.1.0 or later. ... Conditions ... Workaround ... You can use either of the following workarounds: -- Use tmsh to configure multiple LDAP authentication servers. -- Configure a single server IP address via the GUI. ... Fix Information