Operational Defect Database

BugZero found this defect 1091 days ago.

F5 | 970269

Install fails as lind keeps failing due to "Fatal error: block id new probe failed - device file:/dev/cdrom"

Last update date:

5/18/2024

Affected products:

BIG-IP

BIG-IP Install/Upgrade

BIG-IP vCMP

Affected releases:

13.1.3.3

13.1.3.4

13.1.3.5

13.1.3.6

13.1.4

13.1.4.1

13.1.5

13.1.5.1

Fixed releases:

No fixed releases provided.

Description:

Bug ID 970269: Install fails as lind keeps failing due to "Fatal error: block id new probe failed - device file:/dev/cdrom" ... Last Modified: May 18, 2024 ... Related Article: K10486041 ... Symptoms ... Software installation fails and lind restarts. ... In /var/log/daemon.log you see the following log message: logger: Re-starting lind In /var/log/ltm you see the following log message? err lind[<pid>]: 013c0004:3: Fatal error: block id new probe failed - device file:/dev/cdrom The SSH CLI repeats " Emergency Logger: restarting lind" ... Impact ... 1 If 'ls -l /dev/cdrom' reports the file does not exist, then recreate it with # ln -s /dev/sr0 /dev/cdrom Note: If the above workaround does not fix the issue, consider the below steps to continue. ???? ... If you performed an installation attempt, it will be required to remove a regenerated files due the "lind" restarts, 1 List the generated files, # ls /tmp/ | grep lind Example output : lind_util.0eG2cP lind_util.0Eh1sQ lind_util.0IRL3L...