Operational Defect Database

BugZero found this defect 956 days ago.

F5 | 985329

Saving UCS takes longer when iControl LX extension is installed

Last update date:

5/14/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

15.1.2

15.1.2.1

15.1.3

15.1.3.1

15.1.4

15.1.4.1

15.1.5

15.1.5.1

15.1.6

15.1.6.1

15.1.7

15.1.8

Fixed releases:

No fixed releases provided.

Description:

Severity: 3-Major ... Symptoms ... The tmsh command 'save sys ucs' takes longer when iControl LX extensions is installed. ... You may also see errors logged in /var/log/restjavad.0.log: [WARNING][211][date and time UTC][8100/shared/iapp/build-package BuildRpmTaskCollectionWorker] Failed to execute the build command 'rpmbuild -bb --define '_tmppath /shared/tmp' --define 'main /var/config/rest/iapps/f5-service-discovery' --define '_topdir /var/config/rest/node/tmp' '/var/config/rest/node/tmp/ac891731-acb1-4832-b9f0-325e73ed1fd1.spec'', Threw:com.f5.rest.common.CommandExecuteException: Command execution process killed at com.f5.rest.common.ShellExecutor.finishExecution(ShellExecutor.java:281) ... at com.f5.rest.common.ShellExecutor.access$000(ShellExecutor.java:33) at com.f5.rest.common.ShellExecutor$1.onProcessFailed(ShellExecutor.java:320) at org.apache.commons.exec.DefaultExecutor$1.run(DefaultExecutor.java:203) at java.lang.Thread.run(Thread.java:748) Errors logged in /var/log/ltm:...