Operational Defect Database

BugZero found this defect 1006 days ago.

F5 | 987949

Error messages erroneously generated during boot up

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP Install/Upgrade

Affected releases:

17.1.0

17.1.0.1

17.1.0.2

17.1.0.3

17.1.1

17.1.1.1

17.1.1.2

17.1.1.3

Fixed releases:

No fixed releases provided.

Description:

Severity: 3-Major ... Symptoms ... During boot up, error messages are found in /var/log/ltm: Could not retrieve DB variable for (provision.datastor): status 0xff00 Write F5 license shared memory device failed err = -5 Dossier data not available from hypervisor. ... Database error (0), get_platform_obj: could not find platform object - hal_mcp_process_error: result_code= for result_operation=eom result_type=eom Setting /sys/kernel/debug/x86/ibpb_enabled failed. ... Request ibpb=0 ignored Blade 2 turned RED: Quorum: perfect time sync, high availability (HA) TABLE offline Device error: init Cannot get pci config register data for device 00:0e:00 ... Impact ... There is no impact on functionality and the error message can be ignored. ... Conditions ... Upgrade BIG-IP software to version 14.1.4.