BugZero found this defect 950 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/25/2024
APM-Clients
APM-Clients TMOS
No affected releases provided.
7.2.2
Symptoms ... - Edge Client connects to old cached IP address of one/many of the hostnames encountered during access policy. - In locked mode Edge Client, authentication in access policy may get stuck and user may see blank page in browser control. ... Impact ... - Edge Client connects to old cached IP address of one/many of the hostnames encountered during access policy. ... If old IP address is not the valid address, authentication may fail or be stuck and user may see blank page in browser control. - Locked mode Edge Client may be stuck on during authentication and user may see blank page in browser control. ... Conditions ... - Authentication/access policy encounters hostnames which have changing IP addresses. - Edge Client has processed the access policy and connected to VPN once and the subsequent attempt happens in 25 minutes in the same instance of Edge Client. - Old IP address is cached by Edge Client for one of the hostnames and the IP address for the said hostname has chan...