Operational Defect Database

BugZero found this defect 747 days ago.

F5 | 996129

The /var partition is full as cleanup of files on secondary is not executing

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP TMOS

Affected releases:

13.0.0

13.0.0 HF1

13.0.0 HF2

13.0.0 HF3

13.0.1

13.1.0

13.1.0.1

13.1.0.2

13.1.0.3

13.1.0.4

13.1.0.5

13.1.0.6

Fixed releases:

No fixed releases provided.

Description:

Bug ID 996129: The /var partition is full as cleanup of files on secondary is not executing ... Last Modified: Apr 26, 2024 ... Severity: 3-Major ... Symptoms ... The system does not boot because the /var partition is full. ... Impact ... The partition housing /var/config/ may become 100% full, impacting future disk IO operation and it may cause unexpected traffic disruption. ... Conditions ... This may be observed on multi-blade vCMP guests and hosts, as well as on multi-blade tenants. ... Workaround ... None