BugZero found this defect 5 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
12/20/2023
FortiFirewall FFW-1801F
FortiFirewall FFW-2600F
FortiFirewall FFW-3980E
FortiFirewall FFW-4200F
FortiFirewall FFW-4400F
FortiFirewall FFW-4401F
FortiFirewall FFW-4801F
FortiFirewall FFW-VM64
FortiFirewall FFW-VM64-KVM
FortiGate FG-1000D
FortiGate FG-1000F
FortiGate FG-1001F
7.2.8
7.4.2
7.4.3
7.4.4
Some FortiGate models on NP6/NP6Lite/NP6xLite platforms experience unexpected behavior due to certain traffic conditions after upgrading to 7.2.8. Traffic may be interrupted momentarily.Workaround: Users impacted by this issue can contact Fortinet Support to request a special build with a fix for this issue. Alternatively, users can disable the processing of traffic by the IPS engine’s nTurbo using the following command:config ips global set np-accel-mode noneend