Some FortiGate models on NP6/NP6Lite/NP6xLite platforms experience unexpected behavior due to certain traffic conditions after upgrading to 7.2.8. Traffic may be interrupted momentarily.

Last update date:

12/20/2023

Affected products:

FortiFirewall FFW-1801F

FortiFirewall FFW-2600F

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-4401F

FortiFirewall FFW-4801F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

Affected releases:

7.2.8

7.4.2

7.4.3

Fixed releases:

7.4.4

Description:

Some FortiGate models on NP6/NP6Lite/NP6xLite platforms experience unexpected behavior due to certain traffic conditions after upgrading to 7.2.8. Traffic may be interrupted momentarily.Workaround: Users impacted by this issue can contact Fortinet Support to request a special build with a fix for this issue. Alternatively, users can disable the processing of traffic by the IPS engine’s nTurbo using the following command:config ips global set np-accel-mode noneend