When workspace configuration save mode is set to manual in the System > Settings, configuration changes made on the primary unit and then saved do not synchronize with the secondary unit when one of the cluster units are rebooted or shutdown after the change.Workaround: set the workspace configuration mode to automatic.

Last update date:

3/14/2024

Affected products:

FortiFirewall FFW-1801F

FortiFirewall FFW-2600F

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-4401F

FortiFirewall FFW-4801F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

Affected releases:

7.2.8

Fixed releases:

No fixed releases provided.

Description:

When workspace configuration save mode is set to manual in the System > Settings, configuration changes made on the primary unit and then saved do not synchronize with the secondary unit when one of the cluster units are rebooted or shutdown after the change.Workaround: set the workspace configuration mode to automatic.