Read-only administrator may encounter a Maximum number of monitored interfaces reached error when viewing an interface bandwidth widget for an interface that does not have the monitor bandwidth feature enabled.

Last update date:

6/8/2023

Affected products:

FortiFirewall FFW-1801F

FortiFirewall FFW-2600F

FortiFirewall FFW-3980E

FortiFirewall FFW-4200F

FortiFirewall FFW-4400F

FortiFirewall FFW-4401F

FortiFirewall FFW-VM64

FortiFirewall FFW-VM64-KVM

FortiGate FG-1000D

FortiGate FG-1000F

FortiGate FG-1001F

FortiGate FG-100E

Affected releases:

7.0.13

7.2.5

7.2.6

7.2.7

7.4.1

7.4.2

7.4.3

Fixed releases:

7.0.14

7.2.8

7.4.4

Description:

Read-only administrator may encounter a Maximum number of monitored interfaces reached error when viewing an interface bandwidth widget for an interface that does not have the monitor bandwidth feature enabled.Workaround: super_admin users can enable the monitor bandwidth feature on the interface first, then the widget can work for read-only administrators.