BugZero found this defect 67 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
9/28/2023
FortiFirewall FFW-1801F
FortiFirewall FFW-2600F
FortiFirewall FFW-3980E
FortiFirewall FFW-4200F
FortiFirewall FFW-4400F
FortiFirewall FFW-4401F
FortiFirewall FFW-4801F
FortiFirewall FFW-VM64
FortiFirewall FFW-VM64-KVM
FortiGate FG-1000D
FortiGate FG-1000F
FortiGate FG-1001F
7.2.6
7.2.7
7.2.8
No fixed releases provided.
Setting the interface configuration inbandwidth or outbandwidth commands stops traffic flow. On the NP7 platform, setting the interface configuration using set inbandwidth or set outbandwidth commands stops traffic flow.Workaround: unset the inbandwidth and outbandwidth in the CLI:config system interface edit unset inbandwidth unset outbandwidth nextend